Logo

MonoCalc

/

Capacitive and Inductive Reactance Calculator

Physics

Component

Solve for

Accepts 4.7, 4.7u, 4u7, 100n or 1e-6.

318.3 Ω

result
Solved from the other two.

Reactances are shown as positive magnitudes. As complex impedances Z_L = +jX_L and Z_C = −jX_C, so the net reactance of L and C in series is X = X_L − X_C: positive is inductive, negative is capacitive.

Capacitive reactance X_C
318.3 Ω
Significant reactance at this frequency1 Ω10 Ω10 kΩ≈ short circuit≈ open circuit

Guidance only: whether a reactance is "large" depends on the impedance of the circuit around it. The bands assume typical signal-level circuits of tens of ohms to tens of kilohms.

Angular frequency ω
314.2 rad/s
ω = 2πf
Susceptance B_C
3.142 mS
B = 1 / X_C
Frequency f
50 Hz
Capacitance C
10 µF

Reactance vs frequency

1 Hz10 Hz100 Hz1 kHz10 kHz100 mΩ1 Ω10 Ω100 Ω1 kΩ10 kΩ100 kΩFrequency (log scale)50 Hz, 318.3 Ω

X_C (falls 1 decade per decade)

Hover or drag across the chart to read values. The span covers three decades either side of the operating frequency, clamped to 1 Hz – 100 GHz.

X_C of 10 µF across frequency

FrequencyX_C

50 Hz

nearest
318.3 Ω

60 Hz

265.3 Ω

1 kHz

15.92 Ω

10 kHz

1.592 Ω

100 kHz

159.2 mΩ

1 MHz

15.92 mΩ

10 MHz

1.592 mΩ

100 MHz

0.1592 mΩ

Worked steps

Formula

X_C = 1 / (2π f C)

Substitute (SI)

X_C = 1 / (2π × 50 Hz × 1.000e-5 F)

Result

X_C = 318.3 Ω

Angular frequency

ω = 2π f = 314.2 rad/s
Ideal-part model
Real capacitors and inductors have a self-resonant frequency (SRF) set by their parasitic inductance or capacitance; above the SRF a capacitor behaves inductively and an inductor capacitively. This tool models ideal parts plus an optional series resistance only.

About This Tool

Capacitive and Inductive Reactance – AC Resistance of C and L

A resistor opposes current the same way at every frequency. Capacitors and inductors do not: their opposition to an alternating current, called reactance and measured in ohms, depends on how fast the signal changes. This reactance calculator works out the AC “resistance” of a single capacitor or inductor at any frequency, solves backwards for the frequency or part value that gives a target reactance, and turns an ideal reactance into a full impedance once you add the part's series resistance.

The two formulas

Capacitive reactance is X_C = 1 / (2πfC). It is inversely proportional to frequency: a 10 µF capacitor shows 318.3 Ω at 50 Hz but only 0.159 Ω at 100 kHz. That is why capacitors block DC and low frequencies yet pass high-frequency signals, and why they work as coupling and bypass parts.

Inductive reactance is X_L = 2πfL. It grows in proportion to frequency, so a 10 mH choke is 62.83 Ω at 1 kHz and more than 6 kΩ at 100 kHz. Inductors pass DC almost freely and increasingly resist fast changes, which is exactly what a filter choke or an RF choke is for.

Rearranging gives the inverse solves the tool offers: C = 1 / (2πfX) and f = 1 / (2πXC) for a capacitor, L = X / (2πf) and f = X / (2πL) for an inductor. When you solve for a part value, the calculator also suggests the nearest E12 and E24 standard values and shows the reactance each one actually gives at your frequency.

From reactance to impedance

Real parts are never purely reactive. An electrolytic capacitor has equivalent series resistance (ESR), and an inductor has the DC resistance (DCR) of its winding. Enter that resistance and the tool combines it with the reactance as a complex impedance Z = R + jX_L or Z = R − jX_C, with magnitude |Z| = √(R² + X²) and phase θ = atan2(±X, R). The phase is positive for an inductor, where current lags voltage, and negative for a capacitor, where current leads.

The ratio of reactance to resistance is the quality factor Q = X / R. For capacitors the reciprocal is quoted instead as the dissipation factor D = tan δ = ESR / X_C, the figure electrolytic datasheets give at 120 Hz. The corner frequency where X = R marks where the resistance starts to dominate: above 1 / (2πRC) a capacitor's impedance flattens onto its ESR, and below R / (2πL) an inductor looks like a plain resistor. The log-log chart draws this as a dashed |Z| curve settling onto a dotted resistance floor.

Current and reactive power

Add an RMS supply voltage and the tool reports the current I = V / |Z|, the reactive power Q = I²X in VAR, the real power P = I²R, the apparent power S = V·I and the power factor cos θ. A 10 µF capacitor across 230 V at 50 Hz, for example, draws about 0.72 A and circulates roughly 166 VAR while dissipating almost nothing, which is the principle behind power-factor correction capacitors and capacitive dropper supplies.

Mains safety
Capacitors connected across mains can store a dangerous charge after power is removed. Use parts rated for the purpose (X or Y class) and a bleeder resistor, and treat any calculated current as a design figure, not a safety guarantee.

Comparing an inductor and a capacitor

In Compare L and C mode the two reactances are shown side by side at one frequency. Because Z_L = +jX_L and Z_C = −jX_C, the net reactance of the pair in series is X_L − X_C: positive means the circuit behaves inductively, negative means capacitively. The two lines cross at the resonant frequency f₀ = 1 / (2π√(LC)), and the ratio X_L / X_C equals (f / f₀)², so it tells you at a glance how far you are from resonance.

Ideal parts only
Every real capacitor has some lead and plate inductance, and every coil has capacitance between its turns. Above the self-resonant frequency the part flips character, so for RF and fast switching work check the manufacturer's impedance-versus-frequency curve rather than relying on the ideal formula alone.

Frequently Asked Questions

Is the Capacitive and Inductive Reactance Calculator free?

Yes, Capacitive and Inductive Reactance Calculator is totally free :)

Can I use the Capacitive and Inductive Reactance Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Capacitive and Inductive Reactance Calculator?

Yes, any data related to Capacitive and Inductive Reactance Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this reactance calculator work?

Pick a capacitor or an inductor, choose which quantity to solve for, and enter the other two. Every value is converted to hertz, farads, henries and ohms first, then X_C = 1/(2πfC) or X_L = 2πfL (or a rearrangement) is evaluated on unrounded numbers, and only the displayed result is scaled to a readable unit.

Why does a capacitor's reactance fall as frequency rises while an inductor's grows?

A capacitor stores charge, and at higher frequencies it has less time to charge up between reversals, so it opposes the current less: X_C is inversely proportional to f. An inductor resists changes in current, and faster changes induce a larger back-EMF, so X_L is directly proportional to f.

What is the difference between reactance and impedance?

Reactance is the imaginary part of impedance and comes only from capacitance and inductance; it stores and returns energy rather than dissipating it. Impedance combines it with resistance as Z = R + jX, so a real part with ESR or winding resistance has |Z| = √(R² + X²) and a phase angle between 0 and ±90°.

Can I type values like 4u7 or 100n?

Yes. A bare number is read in the unit chosen next to the field, while a number with an SI prefix (4.7u, 100n, 2.4G), RKM-style shorthand (4u7, 4R7) or a written unit (100Ω) is read as an absolute value and overrides the unit selector. Lower-case m means milli and upper-case M means mega.

How accurate are the results for real components?

The arithmetic is exact for ideal parts plus an optional series resistance. Real capacitors and inductors also have parasitic inductance or capacitance that creates a self-resonant frequency; near and above it the measured reactance departs sharply from the ideal formula, so check the datasheet's impedance curve for RF or switching work.

What is the dissipation factor of a capacitor?

The dissipation factor D = tan δ = ESR / X_C is the ratio of energy lost to energy stored per cycle, and it is the reciprocal of the quality factor Q. Electrolytic capacitors are often specified by D at 120 Hz; a lower value means a cooler, more efficient part.