Capacitor Energy Calculator – Stored Energy, Usable Energy and Hold-Up Time
A capacitor energy calculator usually answers one question: how many joules sit in a capacitor of capacitance C charged to voltage V. The answer is the textbook formula E = ½·C·V². In practice that number is only half the story. A supercapacitor backing up a microcontroller, a camera-flash capacitor or a car-audio stiffening cap is useful only down to some minimum voltage, and the load decides how quickly it gets there. This tool starts from the capacitor you already have and works through stored energy, usable energy, hold-up time, capacitor sizing, supercapacitor banks and a stored-energy hazard check.
The four linked quantities: E, C, V and Q
Charge, capacitance and voltage are tied together by Q = C·V, and the stored energy can be written three equivalent ways: E = ½·C·V² = ½·Q·V = Q²/(2C). Any two of the four quantities fix the other two, so the stored-energy mode lets you pick which pair you know. A 1 F capacitor at 14.4 V, for example, holds 103.68 J (about 28.8 mWh) and a charge of 14.4 C, which is 4 mAh in battery terms, since 1 mAh = 3.6 C. To give the number a sense of scale, the tool also shows how high that energy could lift a 1 kg mass: just over 10 metres.
Why energy scales with V², and why the last volts are nearly empty
Moving each extra coulomb onto a capacitor takes more work than the last, because the voltage it is pushed against keeps rising. Adding up that work gives the factor of one half and the square of the voltage. The square has a practical consequence. If a circuit runs from a starting voltage V₁ down to a minimum V₂, the energy released is ΔE = ½·C·(V₁² − V₂²), and the usable fraction is 1 − (V₂/V₁)². Dropping from 5 V to 2.5 V releases 75 % of the stored energy, not 50 %. Letting the voltage sag to half its starting value already gives up three quarters of the energy, and the remaining quarter stays stranded in the capacitor.
Hold-up time depends on the load
The same usable energy lasts different lengths of time depending on how the load draws it. The calculator models three common cases:
| Load | Hold-up time | Voltage shape |
|---|---|---|
| Constant power (DC-DC converter) | t = η·C·(V₁² − V₂²)/(2P) | Square-root collapse |
| Constant current (linear regulator, LED driver) | t = C·(V₁ − V₂)/I | Straight line |
| Resistive | t = R·C·ln(V₁/V₂) | Exponential tail |
A constant-power load draws more current as the voltage falls, so it can never run down to 0 V. The current would become infinite, and the calculator asks for a minimum voltage instead. A resistive load is the opposite: it slows down as the voltage drops and, in theory, never reaches zero at all. Switch the tool to minimum capacitance to run the same formulas backwards. Enter the hold-up time you need and it returns the smallest capacitance that delivers it, the next E6 value up, and a figure with a 20 % margin for parts that are often specified at −20 % tolerance.
Capacitor banks: arrangement trades voltage for capacitance
Supercapacitor cells are rated at only 2.5–3 V, so useful modules wire them in series strings. With N cells in series and M strings in parallel, the bank capacitance is M·C_cell/N and the bank voltage is N·V_cell. The total energy is simply N·M times one cell's energy, however the cells are arranged. Six 3000 F, 2.7 V cells in series make a 500 F, 16.2 V module storing 65.6 kJ (about 18 Wh). Series strings need cell balancing: every cell carries the same charge, so a cell with slightly less capacitance ends up at a higher voltage and can be pushed past its rating.
If you also enter the cell mass, the bank mode reports specific energy in Wh/kg. As a rough order of magnitude, supercapacitors store a few Wh/kg while lithium-ion cells store well over a hundred. Capacitors trade that energy density for very high power, long cycle life and simple charging. Charging a capacitor through a resistor also wastes energy, which the RC time constant calculator covers.
Stored-energy hazard check
Every result is compared with voltage-tiered stored-energy thresholds: 100 J below 100 V, 1 J from 100 V to 400 V, and 0.25 J above 400 V. These figures are approximate, based on secondary summaries of NFPA 70E Article 360 (2021 edition onward) rather than the standard's own text. Older guidance used a single 10 J threshold at 100 V and above. A camera-flash capacitor at 330 V holds about 18 J, many times its threshold, which is why such parts deserve respect long after the device is switched off.