Logo

MonoCalc

/

Inductors in Series and Parallel Calculator

Physics
2 to 8

Inductances add, so L_eq is always at least the largest member. Every inductor carries the same current, and each takes a share of the voltage proportional to its inductance.

2 / 50 rows

Paste a list instead

Commas, spaces or new lines separate values. A suffix such as uH, µ, m or n overrides this unit.

Circuit conditions (optional)

For energy, current split and rating checks.
For reactance, Q and the DCR analysis.
Equivalent inductance · Series
32 µH
Series: 32 µHParallel: 6.875 µH

Series L_eq (32 µH) is at least the largest member (22 µH), as it must be.

Assumes no mutual coupling between any pair of inductors. Use the coupled-pair tab when two coils share flux.

L110 µHL222 µH

Network totals

Equivalent inductance L_eq32 µHL_eq = L₁ + L₂ + … + Lₙ
Same parts in parallel6.875 µH1/L_eq = 1/L₁ + 1/L₂ + … + 1/Lₙ
Nearest E6 value33 µH+3.13 % from L_eq
Nearest E12 value33 µH+3.13 % from L_eq
Nearest E24 value33 µH+3.13 % from L_eq

Per-inductor breakdown

InductorLVoltage share
L110 µH31.25 %
L222 µH68.75 %

Voltage share (L_k / L_eq)

L131.3 % of VL268.8 % of V

Worked steps

StepWorking
FormulaL_eq = L₁ + L₂ + … + Lₙ
Substitute (display units)L_eq = 10 µH + 22 µH = 32 µH
Substitute (henries)L_eq = 1.000e-5 H + 2.200e-5 H = 3.200e-5 H

About This Tool

Inductors in Series and Parallel – Equivalent Inductance, Current Sharing and Coupling

Inductors combine the same way resistors do, as long as their magnetic fields do not interact. In series the inductances add, L_eq = L₁ + L₂ + … + Lₙ, and in parallel the reciprocals add, 1/L_eq = 1/L₁ + 1/L₂ + … + 1/Lₙ. This inductors in series and parallel calculator does both for up to 50 parts with mixed units, and then goes further than the textbook formulas: it handles winding resistance, frequency, rated current and mutual inductance between two coils.

The two basic rules

A series chain carries one current through every coil, so the voltages, and with them the flux linkages, add. The result is always at least as large as the largest member, and each inductor takes a share of the voltage equal to L_k/L_eq. A parallel bank puts the same voltage across every coil, so the result is always at most the smallest member. For exactly two in parallel the reciprocal sum reduces to product over sum, L₁·L₂/(L₁ + L₂). The worked example of 10, 22 and 47 µH gives 79 µH in series and 5.998 µH in parallel.

The stored energy follows from E = ½·L·I². In series every inductor sees the full current I; in an ideal parallel bank the current divides inversely to inductance, I_k = I·L_eq/L_k. Either way the per-inductor energies add up to ½·L_eq·I², and the calculator shows that check next to the breakdown table.

Paralleling inductors to share current: DC versus AC

This is where real parts surprise people. At DC an inductor has no reactance, only its DC resistance (DCR), so the steady current divides by conductance, I_k = I·(1/R_k)/Σ(1/R_j), and has nothing to do with inductance. At high frequency the reactance dominates and the split follows L_eq/L_k. Take a 10 µH, 50 mΩ part in parallel with a 22 µH, 200 mΩ part: at DC the split is 80 % / 20 %, at 100 kHz it is 68.75 % / 31.25 %. If both are rated 3 A, the AC split allows 4.36 A in total but the DC split only 3.75 A, so the lower figure is the real limit.

Size for the worse of the two splits
Switching regulators carry both a DC current and a ripple current. Check each inductor against the DC split for saturation and heating, and against the AC split for ripple.

Effective inductance versus frequency

With DCR included each branch is a complex impedance Z_k = R_k + jωL_k. A series chain stays simple, R_s = ΣR_k and L_s = ΣL_k at every frequency. A parallel bank is Z_eq = 1/Σ(1/Z_k), and its effective series inductance L_s = Im(Z_eq)/ω moves between two limits: the ideal parallel value at high frequency and Σ(L_k·G_k²)/(ΣG_k)² at low frequency, where G_k = 1/R_k. For the pair above that is 7.28 µH near DC and 6.875 µH above about 10 kHz. The curve is flat only when every branch has the same L/R ratio. The tool also reports Q = Im(Z)/Re(Z) and the time constant τ = L_s/R_s.

Mixed networks

For ladders and coursework problems, build up to ten groups, wire each group in series or parallel, then combine the groups. The tool shows the reduction step for every group and then the final combination.

Coupled inductors and mutual inductance

When two coils share flux, the rules above no longer hold. With mutual inductance M = k·√(L₁·L₂), series aiding gives L₁ + L₂ + 2M and series opposing L₁ + L₂ − 2M. In parallel, L_eq = (L₁L₂ − M²)/(L₁ + L₂ ∓ 2M). For 4 mH and 9 mH at k = 0.5, M = 3 mH, and the four results are 19, 7, 3.857 and 1.421 mH. In parallel aiding, once M exceeds the smaller inductance, that coil’s current reverses and a circulating current flows between the two. The calculator flags this case.

To find M for real coils, measure the series pair both ways round: M = (L_aid − L_opp)/4, and half the sum of the two readings should equal L₁ + L₂.

Finding the missing inductor

Given the parts you already have and a target, the design tab solves L_x = L_target − ΣL_k in series or 1/L_x = 1/L_target − Σ1/L_k in parallel, then shows the nearest E12 and E24 values and what each one actually gives. If the target cannot be reached that way, it suggests the other topology instead.

Practical limits
Inductors are usually ±10–20 % parts, so the tolerance band is often wider than the difference between design choices. Saturation current, core losses and self-resonance are not modelled beyond the rated current you enter.

Frequently Asked Questions

Is the Inductors in Series and Parallel Calculator free?

Yes, Inductors in Series and Parallel Calculator is totally free :)

Can I use the Inductors in Series and Parallel Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Inductors in Series and Parallel Calculator?

Yes, any data related to Inductors in Series and Parallel Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this inductors in series and parallel calculator work?

Enter each inductor with its own unit (pH, nH, µH, mH or H) and choose series or parallel. Every value is converted to henries first; series inductances add directly and parallel ones add as reciprocals. The per-inductor currents, energies and voltage shares are all derived from the single unrounded L_eq, so they add back up exactly.

Why do two parallel inductors not share current the way their inductances suggest?

At high frequency the current divides inversely to inductance, but at DC an inductor is just its winding resistance, so the steady current divides by DCR instead. A 10 µH/50 mΩ part in parallel with a 22 µH/200 mΩ part takes 80 % of the DC current but only 68.75 % at high frequency. Enter the DCRs to see both splits and the stricter current limit.

What is mutual inductance and when does it matter?

Mutual inductance M is the part of one coil's flux that links the other, M = k·√(L1·L2) with coupling coefficient k between 0 and 1. Coils on a common core or placed close together couple, and then series aiding gives L1 + L2 + 2M while series opposing gives L1 + L2 − 2M. The coupled-pair tab handles all four series and parallel, aiding and opposing cases.

How can I measure the mutual inductance of two coils?

Connect them in series and measure with an LCR meter, then reverse one coil and measure again. The difference of the two readings divided by four is M, and half their sum is L1 + L2. If the 'aiding' reading comes out lower, the dots were simply the other way round.

Why does the effective inductance of a parallel bank change with frequency?

Each branch is really R + jωL. Unless every branch has the same L/R ratio, the current split moves from resistance-controlled at low frequency to inductance-controlled at high frequency, so the effective series inductance drifts between the two limits. The frequency sweep chart shows the transition around the branch corner frequencies.

What does this calculator leave out?

Modes other than the coupled pair assume no coupling between inductors. Core saturation is only checked against the rated current you enter, and self-resonance and winding capacitance are not modelled, so results above about 100 MHz are indicative only. Coupling among three or more coils needs a full inductance matrix and is out of scope.