Inductors in Series and Parallel – Equivalent Inductance, Current Sharing and Coupling
Inductors combine the same way resistors do, as long as their magnetic fields do not interact. In series the inductances add, L_eq = L₁ + L₂ + … + Lₙ, and in parallel the reciprocals add, 1/L_eq = 1/L₁ + 1/L₂ + … + 1/Lₙ. This inductors in series and parallel calculator does both for up to 50 parts with mixed units, and then goes further than the textbook formulas: it handles winding resistance, frequency, rated current and mutual inductance between two coils.
The two basic rules
A series chain carries one current through every coil, so the voltages, and with them the flux linkages, add. The result is always at least as large as the largest member, and each inductor takes a share of the voltage equal to L_k/L_eq. A parallel bank puts the same voltage across every coil, so the result is always at most the smallest member. For exactly two in parallel the reciprocal sum reduces to product over sum, L₁·L₂/(L₁ + L₂). The worked example of 10, 22 and 47 µH gives 79 µH in series and 5.998 µH in parallel.
The stored energy follows from E = ½·L·I². In series every inductor sees the full current I; in an ideal parallel bank the current divides inversely to inductance, I_k = I·L_eq/L_k. Either way the per-inductor energies add up to ½·L_eq·I², and the calculator shows that check next to the breakdown table.
Paralleling inductors to share current: DC versus AC
This is where real parts surprise people. At DC an inductor has no reactance, only its DC resistance (DCR), so the steady current divides by conductance, I_k = I·(1/R_k)/Σ(1/R_j), and has nothing to do with inductance. At high frequency the reactance dominates and the split follows L_eq/L_k. Take a 10 µH, 50 mΩ part in parallel with a 22 µH, 200 mΩ part: at DC the split is 80 % / 20 %, at 100 kHz it is 68.75 % / 31.25 %. If both are rated 3 A, the AC split allows 4.36 A in total but the DC split only 3.75 A, so the lower figure is the real limit.
Effective inductance versus frequency
With DCR included each branch is a complex impedance Z_k = R_k + jωL_k. A series chain stays simple, R_s = ΣR_k and L_s = ΣL_k at every frequency. A parallel bank is Z_eq = 1/Σ(1/Z_k), and its effective series inductance L_s = Im(Z_eq)/ω moves between two limits: the ideal parallel value at high frequency and Σ(L_k·G_k²)/(ΣG_k)² at low frequency, where G_k = 1/R_k. For the pair above that is 7.28 µH near DC and 6.875 µH above about 10 kHz. The curve is flat only when every branch has the same L/R ratio. The tool also reports Q = Im(Z)/Re(Z) and the time constant τ = L_s/R_s.
Mixed networks
For ladders and coursework problems, build up to ten groups, wire each group in series or parallel, then combine the groups. The tool shows the reduction step for every group and then the final combination.
Coupled inductors and mutual inductance
When two coils share flux, the rules above no longer hold. With mutual inductance M = k·√(L₁·L₂), series aiding gives L₁ + L₂ + 2M and series opposing L₁ + L₂ − 2M. In parallel, L_eq = (L₁L₂ − M²)/(L₁ + L₂ ∓ 2M). For 4 mH and 9 mH at k = 0.5, M = 3 mH, and the four results are 19, 7, 3.857 and 1.421 mH. In parallel aiding, once M exceeds the smaller inductance, that coil’s current reverses and a circulating current flows between the two. The calculator flags this case.
To find M for real coils, measure the series pair both ways round: M = (L_aid − L_opp)/4, and half the sum of the two readings should equal L₁ + L₂.
Finding the missing inductor
Given the parts you already have and a target, the design tab solves L_x = L_target − ΣL_k in series or 1/L_x = 1/L_target − Σ1/L_k in parallel, then shows the nearest E12 and E24 values and what each one actually gives. If the target cannot be reached that way, it suggests the other topology instead.