Logo

MonoCalc

/

Internal Resistance and EMF Calculator

Physics

Solve circuit

Inputs

To find I, enter: ε, r, R · or V, R · or ε, V, r. Leave other fields blank, or fill them to check consistency.

I = ε / (R + r)I = V / RI = (ε − V) / r
Fills ε and r with typical, approximate values to explore.
Results

Current I

2.000 A

Terminal voltage V

11.00 V

EMF ε

12.00 V

Internal resistance r

500.0 mΩ

Load resistance R

5.500 Ω

Lost volts I·r

1.000 V

Short-circuit current ε/r

24.00 A

Total power ε·I

24.00 W

Power in load I²R

22.00 W

Power wasted in r (I²r)

2.000 W

Efficiency η = R/(R + r)

91.67 %

Maximum power ε²/4r (at R = r)

72.00 W

Load is 11.0× r: 91.7 % efficient, 30.6 % of the maximum possible power.

Circuit
Real source+ε = 12.00 Vr = 500.0 mΩlost voltsI·r = 1.000 VI = 2.000 AVV = 11.00 VR = 5.500 ΩA (+)B (−)

Where the EMF goes: ε = V + I·r

Terminal voltage V (load): 11.00 V (91.7 %)

Lost volts I·r: 1.000 V (8.33 %)

V–I characteristic

A straight line from (0, ε) to (I_sc, 0) with slope −r. The dot marks the current operating point.

Power transfer and efficiency

The load gets the most power, 72.00 W, when R = r, but then half of the power is wasted inside the source. High efficiency needs R ≫ r.

Power breakdown

Load I²R: 22.00 W (91.7 %)

Inside source I²r: 2.000 W (8.33 %)

Total power from the EMF ε·I = 24.00 W

Step-by-step working

1. Current I

I = ε / (R + r)I = 12.00 V / (5.500 Ω + 500.0 mΩ) = 2.000 A

2. Terminal voltage V

V = ε·R / (R + r)V = 12.00 V × 5.500 Ω / (5.500 Ω + 500.0 mΩ) = 11.00 V

3. Lost volts

V_lost = I·rV_lost = 2.000 A × 500.0 mΩ = 1.000 V

4. Short-circuit current

I_sc = ε / rI_sc = 12.00 V / 500.0 mΩ = 24.00 A

5. Total power

P_total = ε·IP_total = 12.00 V × 2.000 A = 24.00 W

6. Power in the load

P_load = I²·RP_load = (2.000 A)² × 5.500 Ω = 22.00 W

7. Power wasted in r

P_int = I²·rP_int = (2.000 A)² × 500.0 mΩ = 2.000 W

8. Efficiency

η = R / (R + r)η = 5.500 Ω / (5.500 Ω + 500.0 mΩ) = 91.67 %

9. Maximum power (at R = r)

P_max = ε² / (4r)P_max = (12.00 V)² / (4 × 500.0 mΩ) = 72.00 W

About This Tool

Internal Resistance and EMF Calculator – Lost Volts, Power and Lab Fits

A battery is not a perfect voltage source. Connect a lamp and the voltage across its terminals drops a little; connect a starter motor and it drops a lot. The standard model explains this with two numbers: an ideal electromotive force (EMF) ε in series with a small internal resistance r. This internal resistance and EMF calculator solves that model for any unknown, extracts ε and r from lab readings, combines identical cells, and shows where the power goes.

Why real sources have internal resistance

Inside a cell, charge has to travel through the electrolyte, across the electrode surfaces and along the current collectors. Each of these resists the flow, and together they behave like a resistor hidden inside the battery. The resistance depends on the chemistry, the size of the electrodes, the temperature, the state of charge and the age of the cell, so it is never perfectly constant, but over a modest range of currents it is close enough to treat as a single value.

Lost volts and terminal voltage

When a current I flows, part of the EMF is dropped across r. That drop, I·r, is often called the lost volts. What is left appears at the terminals:

V = ε − I·r and, with an external load R, I = ε / (R + r).

With no current flowing there are no lost volts, so the open-circuit voltage equals the EMF. This is why a high-impedance voltmeter on an unloaded battery reads ε. At the other extreme, shorting the terminals (R = 0) gives the largest current the source can supply, the short-circuit current I_sc = ε / r. When a charger pushes current into the source instead, the drop reverses and V = ε + I·r, so a charging battery always reads above its EMF.

The school lab method: plot V against I

Rearranging gives V = −r·I + ε, the equation of a straight line. Vary a rheostat, record several pairs of current and terminal voltage, and plot V against I. The gradient is −r and the V-intercept is ε; extending the line to V = 0 gives the short-circuit current. The lab data fit mode does this with ordinary least squares and reports standard errors and R², and the residual column makes outliers easy to spot. With only two readings the line is fixed exactly by r = (V₁ − V₂) / (I₂ − I₁), and with an open-circuit reading plus one loaded reading r = (ε − V) / I.

Lab tip
Take readings quickly and let the cell rest between them. Large currents warm the cell and change its internal resistance, which bends the V–I line and lowers R².

Maximum power transfer versus efficiency

The power delivered to the load is P = I²·R = ε²·R / (R + r)². It is zero for a short circuit, zero for an open circuit, and peaks when R = r, where P_max = ε² / (4r). But at that point the same current flows through two equal resistances, so half the power heats the source and the efficiency, η = R / (R + r), is only 50 %. High efficiency needs R ≫ r. Power grids and battery packs are therefore designed to operate far from the maximum-power point, while audio and radio circuits often match R to r on purpose because the signal power matters more than the energy wasted.

Car batteries and coin cells

A starter motor needs hundreds of amps. With an EMF of about 12.6 V, that is only possible if r is a few milliohms; even then the terminal voltage sags noticeably while cranking. A CR2032 coin cell has a respectable 3 V EMF, but its tiny electrodes give an internal resistance of tens of ohms. Its short-circuit current is only around a tenth of an amp, and drawing even a few tens of milliamps drops the terminal voltage sharply, which is why coin cells suit watches and sensors rather than motors.

Combining cells

Putting n identical cells in series adds their EMFs and their internal resistances. Putting m such strings in parallel keeps the EMF but divides the resistance by m:

ε_total = n·ε, r_total = n·r / m, and each cell carries I / m.

Parallel strings are how packs raise their current capability and lower their voltage sag. The model assumes matched cells; mismatched cells in parallel push circulating currents into each other.

Safety
Never short-circuit a real battery to measure its short-circuit current. Lithium and lead-acid cells can deliver enough current to melt wires, start fires or vent hot gas. Use the calculator for that number instead.

Frequently Asked Questions

Is the Internal Resistance and EMF Calculator free?

Yes, Internal Resistance and EMF Calculator is totally free :)

Can I use the Internal Resistance and EMF Calculator offline?

Yes, you can install the webapp as PWA.

Is it safe to use Internal Resistance and EMF Calculator?

Yes, any data related to Internal Resistance and EMF Calculator only stored in your browser (if storage required). You can simply clear browser cache to clear all the stored data. We do not store any data on server.

How does this internal resistance and EMF calculator work?

It models a real source as an ideal EMF ε in series with an internal resistance r, so I = ε / (R + r) and the terminal voltage is V = ε − I·r. You can solve for any one of ε, r, R, I or V, work out ε and r from an open-circuit and a loaded reading, from two loaded readings or from a least-squares fit of a whole table, or combine identical cells in an n × m grid.

What is the difference between EMF and terminal voltage?

The EMF is the energy the source gives each coulomb of charge, and it equals the voltage you measure with no current flowing. The terminal voltage is what is left across the terminals once a current I flows, V = ε − I·r. The difference, I·r, is the 'lost volts' dropped inside the source, so the terminal voltage falls as you draw more current.

Why does maximum power transfer give only 50 % efficiency?

The load receives the most power when R = r, but then the same current flows through two equal resistances, so exactly half the power is dissipated inside the source. Efficiency R / (R + r) only approaches 100 % when the load is much larger than r, which is why power systems run far from the maximum-power point while signal circuits often match R to r.

Why can the calculated internal resistance come out negative?

A negative r means the readings show the terminal voltage rising as more current is drawn, which a passive source cannot do. Common causes are a loaded voltage higher than the open-circuit voltage, readings entered in the wrong order or units, a source that was charging rather than discharging, or noise when two readings are very close together.

How accurate are the typical battery internal resistance presets?

They are rough midpoints of commonly quoted ranges and are only meant for exploring. Real internal resistance depends on chemistry, cell size, temperature, state of charge, age and how it is measured (1 kHz AC impedance reads lower than a DC pulse test), so check a datasheet or measure your own cell for real work.

Why does the two-reading method only need two measurements?

The model V = ε − r·I is a straight line with two unknowns, so two points at different currents fix both the slope (−r) and the intercept (ε). More readings do not change the model, but a least-squares fit through several points averages out meter error and shows, through R² and the residuals, whether the source really behaves linearly.